MXL FORCE METROLOGY
Menu

Home / 6-Axis Load Cells / Miniature selection

MXL-6D / Fingertip & compact tooling

Miniature 6-Axis Force/Torque Sensors

Specify the complete micro force/torque measurement package: six component ranges, tool-offset moments and a usable low-force signal.

+Fx / Mx+Fy / My+Fz / Mz
Miniature six-axis sensor architecture reference with circular sensing body and cable
Supplier-derived AI architecture reference; configuration dimensions and MXL model identity require an approved drawing.

Start with the measured components

Small enough to fit. Sensitive enough for the task.

A micro six axis force torque sensor measures Fx, Fy, Fz and Mx, My, Mz about a defined origin. Its body diameter is only one selection constraint. Include mounting plates, screw engagement, cable movement and the external digitizer in the installed envelope.

Requested MXL configurations, not approved product specifications. Model numbers do not establish a diameter or interchangeability.
RequestForce targetMoment targetReference for reviewNext step
MXL-6D17Micro-force envelope by requestMicro-moment envelope by requestATI Nano17Review MXL-6D17
MXL-6D27Around 50 N requestedAround 1 N·m requestedInterface 6A27 / ME K6D27Review MXL-6D27
MXL-6D4020–500 N requested1–20 N·m requestedATI Mini40 / Interface 6A40Review MXL-6D40

Dimensions, combined-load limits, crosstalk, overload, noise and environmental protection remain configuration approval items. For bulk sourcing, ask for quantity tiers, manufacturer verification and country-of-origin documentation with the configuration review.

Only Fx, Fy and Fz?

A miniature three-axis load cell may fit a force-only fingertip measurement. Include local moments in the mechanical load review even when they are not measured.

Need contact torsion or a six-component wrench?

Select a six-axis force/torque configuration. Define the moment origin and the contact offset before deciding whether a given force range is sufficient.

Compare the full six-axis family →

Calculate your signed tool-offset load case →

Worked load-path example

A small contact force can use the moment range first.

Assume a 10 N force perpendicular to a 30 mm tool offset. The applied moment at the sensor is 0.30 N·m, before adding tool weight, acceleration or other loads. This is a geometry example, not an MXL rated operating point.

|M| = |r × F| = 0.030 × 10 = 0.30 N·m

A tare command removes a signal offset; it does not remove the physical load or restore the mechanical overload margin. Use the sensor-origin wrench for the combined-load check and define the desired contact frame separately.

Concept diagram of a ten newton perpendicular contact force at a thirty millimeter offset, generating a 0.30 newton meter moment at the sensor origin
Original schematic, not to scale. Perpendicular force assumed; use the vector cross product for other directions.

Reference: ATI DAQ manual, calibration matrix and tool-transformation sections. The manual links the matrix to the sensor serial number and distinguishes raw strain channels from resolved force/torque components.

Measure a useful signal

Specify resolution together with bandwidth.

Minimum useful contact

State the smallest force and moment change you need to distinguish, with units. Request measured RMS noise at the chosen sample rate and filter setting. ADC bit depth alone is insufficient.

Time and control loop

Define sample rate, acquisition synchronization, effective bandwidth and end-to-end delay separately. A fast bus or sample clock does not by itself establish closed-loop performance.

Cables and mounting

Show the complete fingertip or tool assembly. Cable drag, mounting preload and a parasitic contact across the sensing structure can affect a low-force measurement.

Signal path from independent bridges or matrix-coupled channels through synchronized acquisition and calibration to controller engineering units
Acquisition architecture overview. Confirm the actual raw-channel count, matrix processing and interface for your configuration.
Plan the synchronized DAQ and electrical interface →

Published reference / reviewed 31 October 2026

Read the range and the dimensional stack together.

As a third-party reference, ATI lists the Nano17 at Ø17 mm × 14.5 mm with standard interface plates. Its SI-50-0.5 calibration lists Fx/Fy 50 N, Fz 70 N and moments of 500 N·mm, equivalent to 0.5 N·m. Those are ATI reference values, not approved MXL specifications.

Read the ATI Nano17 calibration and physical-specification tables. Verify the exact calibration, plate version and simultaneous-load graph rather than treating the model name as a complete specification.

Questions before you specify

Do I need three axes or six axes in a fingertip?

Three force components can describe a resultant contact force. Add three measured moments when torsion, contact offset or a tool-center-point wrench is part of the measurement task. Both choices still need a combined-load review.

Does the MXL-6D17 name confirm a 17 mm sensor?

No. MXL identifiers describe requested configurations. An approved MXL drawing must establish the body, interface plates, connector and cable envelope. ATI reference dimensions describe the ATI product only.

Is a micro six-axis force torque sensor available for production?

Request a configuration review with six component ranges, simultaneous loads, envelope, noise and interface needs. MXL pricing, production capability and delivery are confirmed in the written quotation.

Send the fingertip or tool load case.

Include six peak loads, simultaneous loading, contact offset, minimum useful signal, envelope, bandwidth, quantity and receiving controller. Request the drawing and calibration scope with the sensor.